LIFTjournal 1/2020

Every year in Germany alone, lifts are responsible for up to 500 million euros in avoidable energy costs. The reason for this is the permanently attached opening for the legally prescribed ventilation and smoke extraction of the lift shaft, which to this day is still to be found in most lifts. As a result, lift opera- tors are literally throwing money out the window. A ccording to the calculations of the Central Associ- ation of the Electrical Engineering and Electronics Industry, an average lift shaft of 19 m in height with six landings causes avoidable energy costs of about 1,000 euros annually through the permanently open smoke extraction area. Sealed external envelopes, as called for by the Energy Savings Ordinance (EnEV) or buildings according to the passive building standard cannot be reconciled with a permanently opened smoke extraction opening at all. An optimal solution that reconciles fire protection, ven- tilation and the requirements of the EnEV are automatic lift smoke extraction systems (ASE), which are also suitable for controlled ventilation. In normal operation, the smoke extraction opening is closed to ensure no heat is lost. If the system identifies smoke in the lift shaft, an electric drive opens the shaft head to ensure toxic gases and smoke can escape. The opening in the shaft head for ventilation is also opened automatically in the event of deterioration of the air quality in the lift shaft in suitable systems. The structure of a lift shaft smoke extraction system consists of a controller, sensors for fire or smoke detec- tion and to measure the air quality as well as electrically operated roof or facade elements to open the shaft head. RELIABLE SMOKE DETECTION Smoke detection in the lift shaft can also be realised by an aspirating smoke detector and by point or linear smoke detectors. Point detectors are found mainly in flats and smaller lift shafts while linear smoke detectors also monitor large distances. Systems that are suitable and licensed for this also cover the use of an existing fire alarm system for detecting fire in the lift shaft. VENTILATION OF LIFTS Adequate ventilation of the lift shaft is equally important. In normal operation, air exchange is as a rule guaranteed by the ventilation openings in the car. If the car comes to a standstill as a result of a malfunction or in the event of maintenance, the air exchange has to be secured by an opening in the shaft. Measurements have shown that health-threatening CO 2 concentrations are already reached within a few minutes of a standstill in the car. In this case, a lift shaft smoke extraction system auto- matically opens the roof or façade elements. If temperature, air quality or CO 2 in values are exceeded, controlled natural ventilation is also possible as an option via sensors in suitable systems. OPENING THE SHAFT HEAD Natural smoke and heat extraction devices guarantee reli- able actuation of smoke extraction or ventilation opening, which if used in roof hoods have to be certified for hori- zontal use. Light domes without a wind and rain-dependent control are not suitable. Consequently, slat elements with integrated closing element and weather protection are normally used. The patent EP 1890956 has been applied for in connec- tion with the ventilation of lifts. Operators should clarify with the manufacturer of the lift shaft smoke extraction system whether patent use exists or whether the payment of licence fees is incurred. ⇤ aumueller-gmbh.de RAMONA MEINZER The author is the chair of the management board at Aumüller Aumatic GmbH, a manufacturer of system components for the automation of windows for controlled natural ventilation and smoke and heat extraction. In vielen Aufzügen finden sich auch heute noch dauerhafte Ent­ rauchungsöffnungen, durch die große Energie- mengen entweichen. To this day there are still permanent smoke extrac- tion openings in many lifts, through which large quantities of energy escape. Photo: © polack/stock.adobe.com 13 AUFZUGSBETREIBER  LIFT OPERATORS

RkJQdWJsaXNoZXIy MjU0Mjk=